Understanding stair rise and run
Measure the total finished floor-to-floor rise and the horizontal space available. Choose a preferred maximum riser height consistent with the requirements for your project.
For a 2.8 m rise and a preferred maximum of 0.18 m, rounding 2.8 ÷ 0.18 upward gives 16 risers. Each is 175 mm high. With the upper floor as the landing, there are 15 treads. A 4.2 m run therefore gives a 280 mm going.
The drawing follows the entered rise and run. It does not check headroom, landings, nosings, handrails or local building rules. Establish those constraints separately before construction.